Model 928A Power System Multimeter
|
The Model 928A Power System Multimeter with Floating-Point DSPTM Digital Signal Analysis is an AC Power measurement instrument, providing outstanding performance and flexibility in a small, hand-held package. Not only does the Model 928A measure basic data and power quantities, but it also measures power quality including harmonics, flicker, sags, surges and interruptions. Incorporating a graphic LCD display, serial communications, real time clock and an unprecedented combination of features makes the Model 928A the ideal instrument for the power professional.
Inputs
The Model 928A uses two identical input measurement channels capable of measuring either voltage or current. The dual inputs allow for voltage to current, voltage to voltage or current to current measurements with a basic accuracy of 0.1%. The flexible current inputs are compatible with both voltage output and current output CTs. Convenient current transformer calibration tables help eliminate errors introduced by the CTs and lessen their effect on system measurements. A special 0 to 40 mA range allows for accurate low level (< 10 mA) measurements.
Features
The Model 928A includes a bright, 128 x 64 graphic LCD display, a 30-key multifunction backlit keypad, and an isolated serial interface. The Model 928A may be powered either from four AA type cells (alkaline or NiMH) or an optional external, +7 Vdc plug-in power supply.
Accessories
The Model 928A requires an external CT for current measurements, such as the AP0001300 (1000:1) or the AP0009800 (100:1). Optional accessories include a tilt/bail handle, soft case, test leads, external +7 Vdc power supply, and other CTs.
Model 928A Specifications
Input:
- Input Configuration:
- The Arbiter Systems®, Inc. Model 928A Power System MultimeterTM has two identical measurement channels, Channel A and Channel B. Each input channel has a voltage input and a current input. Current inputs are intended for use with external CTs having a nominal output of 0 to 1 Arms or 0 to 1 Vrms. For basic measurements (voltage, current, frequency, and phase angle) any combination of inputs may be used. For power and energy measurements (active power, apparent power, reactive power, and power factor), one voltage and one current must be selected.
- Voltage:
- Input Range 0 to 660 Vrms
- Impedance 1.2 megohm, differential
- Current:
- Input Range 0.01 to 1 Arms (underrange to < 1 mA) (or 0 to 1.2 Vrms)
- Burden 0.01 ohm maximum (current input style) or 100 kohms nominal (voltage input style)
Interface
- Operator Interface:
- Display 128 x 64 graphic LCD
- Keyboard 30 key keypad
- Serial USB
- Memory 512 KB flash
- Data User setups, Real Time Clock, Approximately 400 KB measurement data
Power Requirements
- Batteries (not included):
- Type 4-AA Cells, alkaline or NiMH
- Operation 30 hours typical with alkaline cells. 60 hours typical with NiMH
- External (not included):
- Type +7 Vdc, unregulated
- Current < 100 mA
- Connector 5.5 x 2.0 mm, center positive
Measurements
- Voltage and Current:
- Method Wideband: True rms, 3 kHz Bandwidth
Narrowband: Fundamental magnitude - Accuracy 0.1% of reading (voltage)
0.1% of reading (current)
1% of reading (low current range) - Phase Angle, A-B:
- Range 0 to 360° or ±180°
- Accuracy 0.1°
Underrange < 1° typical - Frequency:
- Range 50 or 60 Hz ±5 Hz
- Accuracy 0.005% of reading
- Harmonics:
- Input Channel A and Channel B, simultaneous
- Range 2nd to 50th Harmonic (50 or 60 Hz fundamental)
- Accuracy 0.1% THD +5% reading
- Display THD; K-factor; Amplitude bar graph; and individual harmonic magnitude and phase (simultaneous)
- Waveform:
- Display Channel A and/or Channel B
- Power / Energy Quantities:
- Range 0 to 99999 MVA or MVAh
±99999 MVAR or MVARh
±99999 MW or MWh
±1.0000 PF, lead or lag - Accuracy 0.1% of VA, for VA, VAR, and W
0.001 PF
General:
- Physical:
- Size 196 x 101 x 38 mm (7.75 x 4 x 1.5 in.)
254 x 229 x 305 mm (10 x 9 x 6 in.), shipping - Weight: 1 kg (2.2 lbs), net
2.3 kg (5 lbs), shipping - Environmental:
- Operating Temperature -10° to +50° C
- Nonoperating Temperature -40° to +75° C
- Humidity Noncondensing
Accessories:
Included:
| Order Number: | Description |
|---|---|
| AP0009700: | Voltage Probe Lead Set |
| PD0030900: | 928A Operation Manual |
Available:
| Order Number: | Description |
|---|---|
| AP0001300: | 1000:1 Clamp-on CT, 1000 A |
| AP0009700: | Voltage Probe Lead Set |
| AP0009800: | 100:1 Clamp-on CT, 100 A |
| AP0011200: | External power supply, +7 Vdc |
| AS0071800: | Model 928A Starter Kit |
| AS0079000: | Universal Test Plug Current Shunt. Allows for the use of a clamp-on CT with a test block. |
| AS0082900: | Model 928A Bail Assembly |
| BT0000201: | Four (4) AA Alkaline cells |
| CA0026106: | USB Data Cable, 6 ft |
| CA0027100: | CT Cable, Current Output |
| CA0027200: | CT Cable, Voltage Output |
| HD0065200: | Soft Carrying Case |
| Mlink: | Interface software |
AS0071800 Starter Kit Includes:
| Order Number: | Description |
|---|---|
| AP0009700: | Voltage Probe Lead Set |
| AP0009800: | 100:1 Clamp-on CT, 100 A |
| AP0011200: | External power supply, +7 Vdc |
| AS0082900: | Model 928A Bail Assembly |
| BT0000201: | Four (4) AA Alkaline cells |
| CA0026106: | USB Data Cable, 6 ft |
| CA0027100: | CT Cable, Current Output |
| HD0065200: | Soft Carrying Case |