Power Sentinel Security
1133's ship with two default users: anon and admin. When PSCSV opens a connection to an 1133, it automatically logs in as anon. As table 2 shows, anon can only acquire broadcast data. Other operations require more permissions. In order to configure the unit the admin account must be logged in. Please see how to disable security for information on how to edit security settings so that everything is available upon initial connect.
Security Features:
- Up to 14 user logins can be added
- Up to 8 character, case sensitive login names / passwords
- Each login name can have any combination of permissions listed below
- PSCSV automatically logs in connections using a special login name anon
Table 1
| Permission | Allowed operations |
|---|---|
| Login | Take up a communication channel. If this isn't set, none of the others are relevant. |
| Receive Data | Receive all broadcast messages, query messages |
| Download Revenue | Download all revenue |
| Erase Revenue | Erase all revenue |
| Download Event | Download all event data |
| Erase Event | Erase all event data |
| Configure | All configuration that isn't security related |
| Administration | Add/Edit/Delete users |
Table 2
| Login Name | Default operations | Default Password |
|---|---|---|
| admin | Everything | 801n60 |
| anon | Login, Receive Data | Not applicable (use button on Login dialog) |
How to set up the 1133 so that everything is available (disabling security):
- Login as admin Connection, Login As... (default password is 801n60).
- Select the menu Connection, Configure, User Logins.
- Select anon from the Login Name dropdown list.
- Select Administer (all other permissions will automatically be selected).
- Hit Apply, PSCSV will update the 1133, then update itself with the new security information from the 1133.
- Test out the new login by logging in as anon.