Published: Thu, 25 Feb 2010 19:04:44 GMT
The latest release is 10 Feb 2010.
1. Bug 599: Problems erasing single log file.
2. Update RS232 output to replace Null (0x00) bytes with space (0x20).
3. Contact the factory to receive this update.
1. Bug 599: Problems erasing single log file.
2. Update RS232 output to replace Null (0x00) bytes with space (0x20).
3. Contact the factory to receive this update.
Published: Thu, 25 Feb 2010 19:03:00 GMT
The latest Host firmware release is 1.10 - 24 Feb 2010.
1. Limit Flicker values to two decimal digits of resolution (match 933 and 1133).
2. Fix potential log data download data corruption problem.
3. Bug 511: Overflow in certain values of Power Quality Config.
4. Set default date to 1 Jan 2010, was 6 Jan 2005 (only used when powered for the first time).
5. Download the combined Host and DSP zip file from our website.
The latest DSP firmware release is 1.04 - 24 Feb 2010
1. Bug 535: Harmonic phase angles fixed.
2. Download the combined Host and DSP zip file from our website.
1. Limit Flicker values to two decimal digits of resolution (match 933 and 1133).
2. Fix potential log data download data corruption problem.
3. Bug 511: Overflow in certain values of Power Quality Config.
4. Set default date to 1 Jan 2010, was 6 Jan 2005 (only used when powered for the first time).
5. Download the combined Host and DSP zip file from our website.
The latest DSP firmware release is 1.04 - 24 Feb 2010
1. Bug 535: Harmonic phase angles fixed.
2. Download the combined Host and DSP zip file from our website.
Published: Thu, 25 Feb 2010 18:58:07 GMT
The latest release is 0.0.5.0 - 17 Feb 2010.
1. Add start-up warning splash screen (warn user about that upload shouldn't be interrupted).
2. Update Linux serial port search to work with Debian.
3. Add capability to run on 64-bit operating systems.
4. This update may be downloaded from our web site.
1. Add start-up warning splash screen (warn user about that upload shouldn't be interrupted).
2. Update Linux serial port search to work with Debian.
3. Add capability to run on 64-bit operating systems.
4. This update may be downloaded from our web site.
Published: Thu, 25 Feb 2010 17:46:06 GMT
The latest release is 0.0.5.0 - 17 Feb 2010.1.128.
1. Add start-up warning splash screen (warn user about that upload shouldn't be interrupted).
2. Update Linux serial port search to work with Debian.
3. Add capability to run on 64-bit operating systems.
4. This update may be downloaded from our web site.
1. Add start-up warning splash screen (warn user about that upload shouldn't be interrupted).
2. Update Linux serial port search to work with Debian.
3. Add capability to run on 64-bit operating systems.
4. This update may be downloaded from our web site.
Published: Thu, 25 Feb 2010 17:36:57 GMT
PSCSV is now version 1.128.
1. Add support for C37.118 CFG-2 messages to be sent via the UDP broadcast port.
2. This update may be downloaded from our web site.
1. Add support for C37.118 CFG-2 messages to be sent via the UDP broadcast port.
2. This update may be downloaded from our web site.
Published: Thu, 25 Feb 2010 17:38:11 GMT
The latest release is 4.12 - 09 Feb 2010.
1. Add support for C37.118 CFG-2 messages to be sent via the UDP broadcast port.
2. Updated how the C37.118 auto UDP start-up functions. The broadcast will no longer be enabled all the time (it can be stopped via the C37.118 stop broadcast command).
3. Relays put into fault state when hardware fault detected..
4. Requires PSCSV v1.128 or newer.
5. This update may be downloaded from our web site.
1. Add support for C37.118 CFG-2 messages to be sent via the UDP broadcast port.
2. Updated how the C37.118 auto UDP start-up functions. The broadcast will no longer be enabled all the time (it can be stopped via the C37.118 stop broadcast command).
3. Relays put into fault state when hardware fault detected..
4. Requires PSCSV v1.128 or newer.
5. This update may be downloaded from our web site.
Published: Thu, 25 Feb 2010 19:00:10 GMT
The latest release is 0.0.8.0 - 24 Feb 2010.
1. Bug 606: 109x uploader typo.
2. Update Linux serial port search to work with Debian.
3. Download this update from our website.
1. Bug 606: 109x uploader typo.
2. Update Linux serial port search to work with Debian.
3. Download this update from our website.
Published: Thu, 25 Feb 2010 17:42:04 GMT
The latest release is 24 Feb 2010
1. Bug 600: Visible satellites can show less than satellites tracked.
2. Updated version of the display firmware (change brightness settings).
3. Download this update from our website.
1. Bug 600: Visible satellites can show less than satellites tracked.
2. Updated version of the display firmware (change brightness settings).
3. Download this update from our website.
Published: Thu, 25 Feb 2010 17:43:27 GMT
The latest release is 1.12 - 18 Feb 2010.
1. Bug 559: Change tabular results, display 0, function key 4 from "PH ABC" to "PH ABCN".
2. Bug 572: Inconsistencies in user interface - Change references to "Sag Swell" to "Power Quality".
3. Bug 591: Rename "DUR", in Sag-Swell setup, to Dwell.
4. Bug 594: Auto log data loss (max log size seems to be around 1032 records - should be able to store upwards of 16,000 records).
5. Bug 595: View auto log - Fixed problem of paging up (using increment of more than 1) from the bottom of the log. (Depending on the increment size, the only record showing might be the one in the edit box).
6. Bug 601: Custom input screen allowed illegal settings.
7. This update may be downloaded from our web site.
1. Bug 559: Change tabular results, display 0, function key 4 from "PH ABC" to "PH ABCN".
2. Bug 572: Inconsistencies in user interface - Change references to "Sag Swell" to "Power Quality".
3. Bug 591: Rename "DUR", in Sag-Swell setup, to Dwell.
4. Bug 594: Auto log data loss (max log size seems to be around 1032 records - should be able to store upwards of 16,000 records).
5. Bug 595: View auto log - Fixed problem of paging up (using increment of more than 1) from the bottom of the log. (Depending on the increment size, the only record showing might be the one in the edit box).
6. Bug 601: Custom input screen allowed illegal settings.
7. This update may be downloaded from our web site.
Published: Wed, 06 Jan 2010 20:45:01 GMT
Hints on how to install Arbiter software and enable the old style .hlp files in Windows 7.
Published: Wed, 06 Jan 2010 20:42:03 GMT
The latest release is 21 Dec 2009.
1. Enhancements to Position Hold Mode.
To update your 1088B please contact techsupport@arbiter.com
1. Enhancements to Position Hold Mode.
To update your 1088B please contact techsupport@arbiter.com
Published: Wed, 06 Jan 2010 20:37:33 GMT
The latest release is 05 Jan 2010
1. IRIG-B IEEE 1344 outputs incorrect year (00 instead of 10).
1. IRIG-B IEEE 1344 outputs incorrect year (00 instead of 10).
Published: Mon, 26 Oct 2009 23:28:23 GMT
The latest release is Sep 2009.
1. Already out-of-date due to the new 928A and 933A data sheets but it is better than the one you have.
2. Contact sales@arbiter.com to order.
1. Already out-of-date due to the new 928A and 933A data sheets but it is better than the one you have.
2. Contact sales@arbiter.com to order.
Published: Mon, 26 Oct 2009 23:27:08 GMT
1. The ranges and their accuracies are the biggest area of updating/clarification.
Published: Mon, 26 Oct 2009 23:26:32 GMT
1. The data sheet still had information from the design/inception stage that did not make it to the final product.
2. The ranges and their accuracies are the biggest area of updating/clarification
2. The ranges and their accuracies are the biggest area of updating/clarification
Published: Wed, 19 Aug 2009 22:29:06 GMT
Published: Wed, 19 Aug 2009 16:41:00 GMT
The latest release is 17 Aug 2009.
1. Fix power-up set defaults: Incorrectly had to wait until "SETUP" key released.
2. Survey calculation improvements.
3. Position Hold improvements.
4. Option 28 broadcast format fixed. Removed the "0x00" that was randomly placed in the Vorne broadcast string. Not visible if using Vorne displays.
To update your 1092A/B/C - 1093A/B/C please contact techsupport@arbiter.com
1. Fix power-up set defaults: Incorrectly had to wait until "SETUP" key released.
2. Survey calculation improvements.
3. Position Hold improvements.
4. Option 28 broadcast format fixed. Removed the "0x00" that was randomly placed in the Vorne broadcast string. Not visible if using Vorne displays.
To update your 1092A/B/C - 1093A/B/C please contact techsupport@arbiter.com
Published: Wed, 19 Aug 2009 18:21:52 GMT
The latest release is 0.7.4 - August 19, 2009.
1. User Interface changes. Replaced abbreviated names with non abbreviated names. Made Programmable Pulse B frequency selection box show/hide in place of the type, polarity, and time selection dropdowns to free up UI space.
1. User Interface changes. Replaced abbreviated names with non abbreviated names. Made Programmable Pulse B frequency selection box show/hide in place of the type, polarity, and time selection dropdowns to free up UI space.
Published: Fri, 31 Jul 2009 00:09:48 GMT
Now reflects newly available options and terminology changes.
Published: Fri, 20 Mar 2009 01:21:04 GMT
The latest release is 0.7.4 - August 19, 2009.
1. User Interface changes. Replaced abbreviated names with non abbreviated names. Made Programmable Pulse B frequency selection box show/hide in place of the type, polarity, and time selection dropdowns to free up UI space.
1. User Interface changes. Replaced abbreviated names with non abbreviated names. Made Programmable Pulse B frequency selection box show/hide in place of the type, polarity, and time selection dropdowns to free up UI space.
Published: Fri, 31 Jul 2009 00:09:27 GMT
Lots of updates to accurately reflect the operation of the Model 1095A/C.
Published: Tue, 28 Jul 2009 00:39:08 GMT
The latest release is 0.0.4.0 - 20 Aug 2008.
1. Updated to support new 933 main board.
1. Updated to support new 933 main board.
Published: Tue, 28 Jul 2009 00:28:03 GMT
The latest release is 25 June 2009.
1. Bug 487: Position hold errors fixed
2. Position display, when in survey mode, updated so all clocks match.
To update your 1084A/B/C please contact techsupport@arbiter.com
1. Bug 487: Position hold errors fixed
2. Position display, when in survey mode, updated so all clocks match.
To update your 1084A/B/C please contact techsupport@arbiter.com
Published: Tue, 16 Jun 2009 18:32:29 GMT
In accordance with Requirement R1.1 of NERC Standard PRC-018-1, Disturbance Monitoring Equipment Installation and Data Reporting, utilities are required to maintain time accuracy of less than 2 ms in all Disturbance Monitoring equipment (DME). Furthermore, as required in PRC-018-1, this time shall be in Coordinated Universal Time (UTC) format. This requirement is reiterated in Paragraph 1.4.1 of NERC CIPCs Security Guideline for the Electricity Sector: Time Stamping of Operational Data Logs (draft version 0.91, dated November 7, 2008).
GPS Clocks manufactured by Arbiter Systems, Inc. provide UTC time in accordance with this requirement. The accuracy of clock timecode outputs (IRIG-B, 1 PPS, and NTP) varies by model and choice of timecode, but always exceeds NERC requirements.
GPS Clocks manufactured by Arbiter Systems, Inc. provide UTC time in accordance with this requirement. The accuracy of clock timecode outputs (IRIG-B, 1 PPS, and NTP) varies by model and choice of timecode, but always exceeds NERC requirements.
Published: Tue, 28 Jul 2009 00:16:22 GMT
Published: Thu, 30 Apr 2009 00:17:32 GMT
Changes and Updates:
1. Installer/Uninstaller updated
2. File->Open is now used only to open previously saved 93X flash files
3. Device->Configure and Device->Download Flash File are now used to configure the device or download a flash file from the device.
4. View->Select Columns is used to select which data columns to display from the download flash file.
5. View->Data Format is used to switch between various flash file formats for which the software was unable to auto-detect the format.
1. Installer/Uninstaller updated
2. File->Open is now used only to open previously saved 93X flash files
3. Device->Configure and Device->Download Flash File are now used to configure the device or download a flash file from the device.
4. View->Select Columns is used to select which data columns to display from the download flash file.
5. View->Data Format is used to switch between various flash file formats for which the software was unable to auto-detect the format.
Published: Thu, 02 Apr 2009 19:04:02 GMT
The 1094B operation manual now includes information about the application software, updates the DC input levels for Option 07 and Option 10 power supplies, and adds information about the new broadcast message (NGTS).
Published: Thu, 02 Apr 2009 19:01:31 GMT
PSCSV is now version 1.122. This is a bugfix release so that PSCSV933 will start on Windows 2000.
Published: Fri, 20 Mar 2009 01:21:09 GMT
Background: The Models 1092 and 1093 had a programmable Daylight Saving Time function named AUTO-CUS. This function could compensate for the new DST rules instead of updating the firmware.
Problem: DST will incorrectly take place one week early in any year where March 1st is on a Sunday (2009, 2015, 2020, 2026, etc.). In other words, the 'Spring Forward' will happen on March 1st instead of March 8th for the problem years.
Recommended solution: Update to the latest firmware.
Work around: Manually turn DST on and off or wait out the week during the problem years.
Problem: DST will incorrectly take place one week early in any year where March 1st is on a Sunday (2009, 2015, 2020, 2026, etc.). In other words, the 'Spring Forward' will happen on March 1st instead of March 8th for the problem years.
Recommended solution: Update to the latest firmware.
Work around: Manually turn DST on and off or wait out the week during the problem years.
Published: Fri, 20 Mar 2009 01:20:43 GMT
The web page is online for the 1095A/C. There is also a web page to grab the software.
Published: Fri, 20 Mar 2009 01:20:33 GMT
Published: Fri, 20 Mar 2009 01:20:20 GMT
All GPS satellite controlled clocks have a position accuracy of 10 meters, rms, 90% confidence.
Published: Fri, 20 Mar 2009 01:20:01 GMT
The circuit board used for Option 32 was redesigned so that it can share with the new Option 33. Option 33 provides a second, independent NTP Server. The changes are more than internal. The rear panel has limited space but required another connector so the RS-232 port was switched from a DB-9 to an RJ-11. It now matches the RS-232 port style on the 933A.
Option 32 data sheet
Option 33 data sheet
Option 32 data sheet
Option 33 data sheet
Published: Fri, 20 Mar 2009 01:16:49 GMT
1088B included power supply rating = 85-264 Vac or 110-350 Vdc
1088Bopt07 = 85-264 Vac or 110-350 Vdc
1088opt15A = 110-170 Vdc
1088opt15B = 110-300 Vdc
1094opt07 and 1094opt10 = 85-264 Vac or 110-350 Vdc
1093opt07 and 1093opt10 = 85-264 Vac or 110-350 Vdc
1084opt07 and 1084opt10 = 85-264 Vac or 110-350 Vdc
1083B = 85-264 Vac or 110-370 Vdc
Published: Thu, 29 Jan 2009 23:40:17 GMT
Fiber-optic to logic adapters and logic to fiber-optic adapters have become quite popular. They now have their own page on the Arbiter web site.
http://www.arbiter.com/catalog/clock/fiber_to_logic_to_fiber/index.php
Copper IRIG-B distribution system modules are now on the web site, too.
http://www.arbiter.com/catalog/clock/copper_irig_distribution/index.php
You may want to read the Application Note 101 for information about Distributing Timing Signals in a High-EMI environment for additional information about the copper IRIG-B distribution system modules.
http://www.arbiter.com/ftp/datasheets/appnote101.pdf
http://www.arbiter.com/catalog/clock/fiber_to_logic_to_fiber/index.php
Copper IRIG-B distribution system modules are now on the web site, too.
http://www.arbiter.com/catalog/clock/copper_irig_distribution/index.php
You may want to read the Application Note 101 for information about Distributing Timing Signals in a High-EMI environment for additional information about the copper IRIG-B distribution system modules.
http://www.arbiter.com/ftp/datasheets/appnote101.pdf
Published: Wed, 12 Nov 2008 20:48:14 GMT
Another leap second will be added to the UTC time scale on 31 December 2008. The Arbiter GPS Satellite Controlled Clocks will not be adversely affected by the addition of a leap second.
Published: Wed, 12 Nov 2008 20:47:18 GMT
The Arbiter Time Service is now version 1.5. The big news is that ATS can now synchronize to the 1094B serial port.
Published: Wed, 12 Nov 2008 20:45:41 GMT
The 928A has an updated manual and starter kit component change. In the starter kit, the current output CT is replaced by a voltage output CT and a standard 1-100A calibration. The voltage output CT's performance is much better than the current output CT.
Published: Mon, 21 Apr 2008 18:36:27 GMT
The Arbiter Systems, Inc. Remote GPS Receiver provides GPS synchronization for the Arbiter Systems' Model 933A (order number AS0077600) and the Doble Model F6150 (order number AS0077601) at the standard GPS frequency (L1 band) of 1575.42 MHz. Thus providing the best timing accuracy for the Model 933A and the Doble Model F6150. Although the remote GPS receiver is sealed against the weather, it is designed for temporary outside operation.
Published: Fri, 21 Mar 2008 00:14:12 GMT
The 1133A Firmware Updater is now release 0.0.4.0.
This release allows for use of serial ports greater than 9.
This release allows for use of serial ports greater than 9.
Published: Tue, 19 Feb 2008 23:11:15 GMT
The Arbiter Systems, Inc. Remote GPS Receiver provides GPS synchronization for the Arbiter Systems' Model 933A (order number AS0077600) and the Doble Model F6150 (order number AS0077601). Thus providing the best timing accuracy for the Model 933A and the Doble Model F6150.
Published: Mon, 17 Dec 2007 22:44:38 GMT
The firmware since release v3.95 - 10May07 is not compatible with the original mainboard of the 1133A known affectionately as the 167 board. The newer mainboard is the 168 board and has been around for a very long time but there may still be demo 1133A's out there with the 167 board so be careful when updating the firmware.
Steps to determine Processor Type:
1. Download the Firmware Updater.
2. Run the Firmware Updater.
3. Click Tools.
4. Click Processor Type.
5. A window will pop up indicating the Processor Type.
6. If the Processor Type is 168 then you have the latest mainboard and the firmware and Firmware Updater are compatible.
7. If the Processor Type is 167 then you have an old mainboard and require an upgrade. Contact the factory for information.
Steps to determine Processor Type:
1. Download the Firmware Updater.
2. Run the Firmware Updater.
3. Click Tools.
4. Click Processor Type.
5. A window will pop up indicating the Processor Type.
6. If the Processor Type is 168 then you have the latest mainboard and the firmware and Firmware Updater are compatible.
7. If the Processor Type is 167 then you have an old mainboard and require an upgrade. Contact the factory for information.
Published: Wed, 31 Oct 2007 22:40:30 GMT
The PMU Connection Tester application was developed by Tennessee Valley Authority (TVA) and verifies that the data stream from any known phasor measurement device is being received. It currently supports the following phasor data protocols: IEEE C37.118 Version 1/Draft 7, IEEE C37.118 Draft 6, IEEE 1344, BPA PDCstream and the Virginia Tech FNET streaming data protocol. Please read TVA's disclaimer.
Published: Fri, 28 Sep 2007 00:11:26 GMT
Do not forget that Daylight Saving Time falls back one hour on November 4th and that is not too far around the corner.
Published: Wed, 11 Oct 2006 00:44:34 GMT
What degree of accuracy is really required? Read this white paper for the answer.
Published: Wed, 11 Oct 2006 00:46:11 GMT
More information about the USA DST changes in 2007.