Model 1093A/B/C GPS Satellite-Controlled Clock (500ns)

Model 1093A/B/C GPS Satellite-Controlled Clock (500ns)

An Arbiter Systems® best seller, Model 1093A/B/C provides accuracy, flexibility and economy to meet a broad range of industry applications.

Model 1092A/B/C/1093A/B/C User manual
Download PDF(2.1 MB) »

Model 1092A/B/C/1093A/B/C User Manual Espanol
Download PDF(1.3 MB) »

Model 1093A/B/C Data Sheet
Download PDF(74.6 kB) »

Model 1093A/B/C delivers better than 500 ns accuracy and includes the most highly sought after features in a precision time clock as standard.

With two terminal strip outputs providing unmodulated IRIG-B and 1 PPS signals, the 1093 is capable of driving multiple loads in parallel. An optional modulated IRIG-B port is available adding greater flexibility.

Like other Arbiter clock models, various options are available to add features such as NTP (Network Time Proocol) support, four additional configurable outputs, high drive IRIG-B outputs, power system time, frequency, and Phase Monitor functions, one Form C (SPDT) fail-safe, LOCKED relay that is compatible with 129 Vdc digital fault recorder inputs; plus many more.

Versions A/B/C offer various interface options (see photos and Key Features tab). Each product includes the GPS antenna and cable, an appropriate power inlet and power cord, a rack mount kit and an operations manual, all backed by a Limited Lifetime Warranty.

Model 1093A/B/C is available with three front panel configurations. See photos and Key Features tab for more information.

  • Accuracy <500 ns typical
  • Unmodulated IRIG-B and 1 PPS included, modulated IRIG-B optional
  • Options include an internal NTP server, High Drive IRIG-B outputs, One Form C (SPDT) fail-safe locked relay, Power System Time,
  • Frequency and Phase Monitor

Versions A/B/C offer various interface options (see photos):

  • 1093A supports four LEDs for monitoring operating status.
  • 1093B adds to the LEDs an LCD display and keypad, providing easy access to setup and system status information.
  • 1093C includes both the operating status LEDs, the LCD display and keypad, and includes a large LED time display.

Receiver Characteristics

Timing Accuracy

Accuracy Note

Specifications apply at the 1 PPS output, in the presence of Selective Availability (SA), as of date of publication

Accuracy UTC/USNO

±500ns peak

Position Accuracy

10 meters, rms, 90% confidence

Satellite Tracking

Twelve (12) channel, C/A code (1575.42 MHz). Receiver simultaneously tracks up to twelve satellites. Results from all tracked satellites are averaged in Position-Hold Mode or, with Position-Hold Mode off, using least-squares estimation.

Acquisition

  • 150 seconds typical, cold start
  • 15 minutes, 90% confidence, cold start
  • 40 seconds, with almanac less than 1 month old
  • 15 seconds, with ephemeris less than 4 hours old
  • The GPS Data Backup Battery is now included in the Model 1093s. This feature improves acquisition time to as little as 15 seconds after a brief power loss by supplying constant power to the real-time clock and RAM in the GPS receiver module.

I/O Configuration

Output Connectors

Two standard: one IRIG-B Unmodulated and one 1 PPS; Type: bus driver, 5 V CMOS; 10 ohms source impedance; ±75 mA drive capability; pluggable terminal strip.
Open-drain FET drivers (400 V, 220 mA, 1 W power dissipation) can also be fitted; contact tech support.

Event Inputs

One event timer channel with 1 µs resolution is standard. This function may be driven by the start bit of a received character on the serial port, or (by internal connection) an external 5 V CMOS/TTL signal at one of the terminal strip connectors.

Programmable Pulse Output

One programmable output pulse (by a jumper connection) that may be output on a terminal strip connector or the AUX OUT pin on either RS-232 Port.
Four modes:

  • Every 1 to 60,000 seconds, starts top of the minute
  • Hourly at a specified offset
  • Daily at a specified time of day
  • One shot at a specified time of year

Pulse duration is programmable from 0.01 to 600 seconds, except in one-shot mode, where the output is Low prior to the specified time and High thereafter.

Interface

Operator

Display
  • Status LEDs (Models 1093A/B/C)
  • 2 x 20 character supertwist LCD (Model 1093B/C)
  • 14 mm (0.56 in.) LED; 9 digits (Model 1093C)
Functions
  • Time: UTC or local
  • Position: latitude, longitude, altitude
  • Receiver and clock status
  • 1 PPS (input) deviation
  • Event time
Status LEDs
  • Operate (green)
  • Unlocked (red)
Keyboard

Eight keys; select display functions or setup menus (Model 1093B/C)

Setup
  • Local time offset
  • Output code select: Local/UTC
  • Daylight Saving Time (Set Summer Time): Off/On/Auto USA/Auto EUR/Auto CUS
  • Backlight control: On/Off/Auto
  • Event input: Event/1 PPS
  • Programmable Pulse setup
  • Antenna delay
  • Out of lock time: 1 to 99 minute(s), Off, or Zero Delay
  • Auto-Survey: On/Off, Survey duration
  • Position Hold: On/Off, Position Auto/Manual
  • Option Configuration and Setup
  • Serial port: RS-232

System

RS-232

1200 to 19,200 baud; 7 or 8 data bits; 1 or 2 stop bits; even/odd/no parity

Second RS-232 port available (1093opt19)
Connector: Male 9-pin D-sub (TXD, RXD)

RS-422/485

Optional driver can also be fitted (1093opt94)

Broadcast modes
  • Standard ASCII (IRIG-J)
  • Extended ASCII
  • ASCII with Time Quality
  • ASCII with Time Quality and Year
  • Vorne large-display time
  • Status/Alarm
  • Event data
Connector

Male 9-pin D-sub (TXD, RXD, AUX IN, AUX OUT)

AUX OUT can provide programmable pulse function at RS-232 levels

Power Requirements

Standard

Voltage

85 to 264 Vac, 47 to 440 Hz, 20 VA maximum or 110 to 350 Vdc, 15 W maximum

Inlet

IEC-320 with fuse and mating cordset. Specify option P01 - P10

Available cordset plug style and specifications are described in the Options and Accessories section.

General

Physical

Size

1 RU rack mount or tabletop, 260 mm deep FMS, Rack mounts included.
508 x 381 x 203 mm (20 x 15 x 8 in.), shipping

Weight

2 kg (4.5 lbs), net
5.5 kg (12 lbs), shipping

Antenna

Cable Connection: F-type
Size: 77.5 dia. x 66.2 mm (3.05 x 2.61 in.)
Weight: 170 grams (6.0 oz)

Antenna Cable

Type: RG-6, 15 m (50 ft) provided
Weight: 0.69 kg (1.52 lbs) per 15 m

Mounting

0.75 in. pipe (1 in. - 14 marine) thread

Environmental

Temperature

Operating: 0 °C to +50 °C (-20 °C to +70 °C typical)
Nonoperating: -40 °C to +75 °C

Humidity

Noncondensing

EMC

Radiated susceptibility: passes walkie-talkie test.

Conducted emissions: power supply complies with FCC 20780, Class A and VDE 0871/6.78 Class A.

Surge withstand capability (SWC), power inlet: designed to meet ANSI/IEEE C37.90-1 and IEC 801-4

Certificates and Approvals

CE mark/label and certificate:

Except as noted otherwise, only one I/O Option may be installed. Available options are listed below and described in the Options and Accessories section.

I/O
1093opt03 Four Additional Configurable Outputs
1093opt19 Second RS-232 Port
1093opt20A Four Configurable Fiber-Optic Outputs
1093opt27 8-Channel High Drive IRIG-B Output
1093opt28 Power System Time, Frequency and Phase Monitor
1093opt29 Four Additional Outputs with Dry Contact and +25/50 Vdc
1093opt32 Internal Network Time Protocol (NTP) Server
1093opt33 Dual Internal Network Time Protocol (NTP) Server
1093opt92 1 IRIG-B Modulated Output
1093opt93 1 Out-of-lock Relay 1 Form C SPDT
1093opt94 1 RS-422/485 Driver
1093opt95 Four BNC Output Connectors, (Parallel to Pluggable Terminal Strip)
1093opt96 1 1 PPS Output Reconfigured to Programmable Pulse
1093opt97 1 IRIG-B Output Reconfigured to Programmable Pulse
1093opt98 1 IRIG-B Modulated Reconfigured to Event Input
General
1093opt01 LCD Backlight
1093opt04 On/Off Switch (1084A/B/1093A/B)
Power (select only one)
1093opt07 IEC-320 Power Inlet 85 to 264 Vac RMS, 110 to 370 Vdc
1093opt08 10 to 60 Vdc Terminal Power Strip and Surge Withstand
1093opt10 85 to 250 Vac RMS, 110 to 350 Vdc Terminal Power Strip and Surge Withstand

1 May be ordered independently from other I/O options

Included
AS0028200 Rack Mount Kit
AS0035400 Operation Manual (1092/1093)
AS0087800 Arbiter Universal GPS Antenna
CA0021315 15 m (50 ft) RG-6 Antenna Cable
P01-P10 1 Country specific power cord with straight female end
Country specific plug and power cord cable with straight female end.
Available
AP0003400 2 BNC (Male) Breakout to 100mm Wires
AP0008900 BNC (Female) Breakout to 100mm Wires
Converts any terminal strip output to BNC.
AS0033100 Rack Slide Kit
AS0044600 GPS Antenna Mounting Kit
AS0044700 3 21 dB In-Line Pre-amplifier
Adds a minimum of 21 dB of gain at the GPS L1 frequency (1.575 GHz), when used with Arbiter Systems GPS-Controlled
Clocks.
AS0044800 RG-11 Crimp Tool + 25 F-type Connectors
AS0048900 Antenna Grounding Block Kit
AS0049000 GPS Surge Protector Kit
AS0062000 High Interference GPS Antenna and Mounting Adapter Kit
CA0021302 2 m (6 ft) RG-6 Antenna Cable
CA0021306 6 m (20 ft) RG-6 Antenna Cable
CA0021330 30 m (100 ft) RG-6 Antenna Cable
CA0021345 45 m (150 ft) RG-6 Antenna Cable
CA0021360 60 m (200 ft) RG-6 Antenna Cable
CA0021375 75 m (250 ft) RG-6 Antenna Cable
CN0027700 F-type, RG-6 Antenna Cable Crimp-on Connector
TF0006000 F-type, RG-11 Antenna Cable Crimp Tool
TF0006400 RG-6 Crimp Tool
TF0013200 Antenna Cable Stripping Tool, RG-6
TF0013300 Antenna Cable Stripping Tool, RG-11
WC0004900 300 m (1000 ft) Roll RG-11 Cable

1 Only applies if Power Option 07 is ordered
2 Requires Opt03
3 Used for cable length greater than 75m (250ft)

GPS Substation Clock Requirements
Download PDF(24.9 kB) »

IRIG-B Time Code Accuracy, IED and System Design Issues
Download PDF(31.4 kB) »

NERC PRC-08 Compliance Statement
Download PDF(75.1 kB) »

Time in the Power Industry: How and Why We Use It
Download PDF(406.8 kB) »

Why GPS Clocks Are Not Free
Download PDF(11.8 kB) »

Continual Self Calibration with Power System Time, Frequency and Phase Monitor Option 28
Download PDF(12.4 kB) »

GPS Antenna Mounting Bracket
Download PDF(63 kB) »

GPS Antenna Mounting Bracket Instructions
Download PDF(129.5 kB) »

GPS Antenna Preamplifier Installation Instructions
Download PDF(152.9 kB) »

IRIG Standard 200-04
Download PDF(2.5 MB) »

IRIG-B Specifications
Download PDF(26.6 kB) »

Internal Network Time Protocol (NTP) Server
Download PDF(22.2 kB) »

Internal Network Time Protocol (NTP) Server Espanol
Download PDF(128.9 kB) »

Option 32: Internal NTP Server Setup and Operation Guidelines
Download PDF(278.7 kB) »

Option 33: Dual Internal NTP Server Setup and Operation Guidelines
Download PDF(300.7 kB) »

Power System Time, Frequency and Phase Monitor
Download PDF(15 kB) »

Windows® Time Service Configuration
Download PDF(14.2 kB) »

Chassis Dimensions
Download PDF(24 kB) »

Clock Option Selection Guide
Download PDF(26.4 kB) »

Clock Selection Guide
Download PDF(26.5 kB) »

Model 1093 Option List Espanol
Download PDF(678.4 kB) »

Timing Products Options and Accessories
Download PDF(42.8 kB) »

Catalogo de Productos de Sincronizacion y Frecuencia
Download PDF(216.1 kB) »

Quick Model Search
Search Arbiter.com
 advanced search help »


phone
(US, Canada, Mexico only) 800.321.3831 805.237.3831

email
sales@arbiter.com