Options - Option 08 10 Vdc to 60 Vdc Terminal Power Strip and Surge Withstand (1088B)

Summary Information


Replaces the standard power supply with one accepting 10 Vdc to 60 Vdc power. Replaces standard IEC-320 inlet with a dc terminal barrier strip. Operates from common low-voltage battery systems, including 12 Vdc, 24 Vdc, and 48 Vdc. Available on the Model 1088B.

Full Description


10 Vdcto 60 Vdc Terminal Power Strip and Surge Withstand (1088B), as installed on rear of chassis.

Replaces the standard power supply with one accepting 10 Vdc to 60 Vdc power. Replaces standard IEC-320 inlet with a dc terminal barrier strip. Operates from common low-voltage battery systems, including 12 Vdc, 24 Vdc, and 48 Vdc. Available on the Model 1088B.

Specifications

Input Power

  • DC Voltage: 10 Vdc to 60 Vdc.
  • Input Power: < 20 Watts, typical.

Terminal Strip

  • Terminal Assignment: Ground, (−), (+). Left to right, viewed from rear.
  • Block Size: 49 mm W x 15mm H x 16.5 mm D. (1.9 in x 0.6 in x 0.6 in)
  • Block Material: Glass-filled thermoplastic.
  • Screw Size: 6–32 x 0.25 in
  • Screw Material: Cadmium-plated steel.
  • Terminal Spacing: 9 mm (0.35 in).
  • Approvals: U.L. recognized; C.S.A. approved.

Fuse

  • Type: Bussman GDC-2A.
  • Current Rating: 2 Ampere, time lag.
  • Voltage Rating: 250 Volts.
  • Size: 5 mm x 20 mm.

Surge Withstand Protection (SWC)

Provides input Surge Withstand Capability (SWC) in compliance with both ANSI C37.90 and IEC 801-4.